Metals testing is a useful measure of contaminants in our environment. We routinely test for metals in soil and metals in various types of water (wastewater, groundwater, storm water and drinking water). We test for high concentrations of contaminants by Inductively Coupled Argon Plasma (ICP) using SW846 6010B and EPA 200.7. Low concentrations are determined by Graphite Furnace Atomic Absorption (GFAA).

Teklab, Inc is a NELAC Accredited Environmental Testing Laboratory that provides testing for metal constituents as required by various regulatory authorities. A listing of our testing methods is shown below.

We recommend that you use a NELAP accredited Environmental Testing Laboratory whether your application requires it or not..

spacer
Teklab Advantage Minimize

Our metals testing customers have an advantage over their competitors

Teklab is a NELAC accredited laboratory with a standard turn-around-time of five business days. We take pride in our ability to handle large one and two day turn-around-time projects. Our customers enjoy the advantage of getting results up to two weeks faster than their competitors. That means you can wrap up a work site and move on to other projects faster and save a tremendous amount of money by not having equipment and personnel waiting around for the laboratory.

spacer
Testing Methods Minimize

EPA Methods

  • 200.7 :- Metals by ICP (Dissolved/Total)
  • 200.9 :- Thallium by GFAA (Dissolved/Total)
  • 204.2 :- Antimony by GFAA (Dissolved/Total)
  • 206.2 :- Arsenic by GFAA (Dissolved/Total)
  • 239.2 :- Lead by GFAA (Dissolved/Total)
  • 270.2 :- Selenium by GFAA (Dissolved/Total)
  • 279.2 :- Thallium by GFAA (Dissolved/Total)
  • 245.1 :- Mercury (Dissolved/Total)
  • 1631 :- Low Level Mercury, PPT (Dissolved/Total)
spacer
Testing Methods Minimize

Standard Methods

  • 3112B :- Mercury (Dissolved/Total)
  • 3113B :- Metals by GFAA (Dissolved/Total)
  • 3120B :- Metals by ICP (Dissolved/Total)
spacer
Testing Methods Minimize

NIOSH Methods

  • 6009 :- Mercury vapor
  • 7082 :- Air cartridges - Lead and several other metals
spacer
Testing Methods Minimize

SW846 Methods

  • 1311 :- Metals in TCLP Extract by ICP/GFAA
  • 1312 :- Metals in SPLP Extract by ICP/GFAA
  • 6010B :- Metals by ICP (Dissolved/Total)
  • 7041 :- Antimony by GFAA (Dissolved/Total)
  • 7060A :- Arsenic by GFAA (Dissolved/Total)
  • 7421 :- Lead by GFAA (Dissolved/Total)
  • 7470A :- Mercury by CVAA(Aqueous)
  • 7471A :- Mercury by CVAA (Soild)
  • 7740 :- Selenium by GFAA (Dissolved/Total)
  • 7841 :- Thallium by GFAA (Dissolved/Total)
spacer
Equipment Minimize

Metals Testing Equipment

  • Leeman Labs ICP
  • Leeman Labs Hydra AFG Cold Vapor Atomic Fluoresence
  • Perkin Elmer FIMS Cold Vapor AA Mercury Analyzer
  • Thermo-Jarrell Ash ICP Spectrophotometer IRIS High Resolution
  • Unicam Graphite Furnace
  • Varian SpectrAA 220Z Graphite Furnace
  • Varian SpectrAA 240Z Graphite Furnace